4 Magnetic latching relay DS907G 120A - 广西睿奕科技开发有限公司 GUANGXI RAMWAY TECHNOLOGY CO LTD latching relay magnetic relay
Products Magnetic latching relay DS907G 120A

产品特性:

1.DS907G 120A is mainly used on export-type watches to replace two single-phase relays. The outlet mode is 1 in 2 out, 3 in 4 out. 2.The contact resistance can be below 0.8 milliohms for a long time, reaching UC2, UC3, and TUV requirements. 3.The overall heating condition is 50K at a rated current of 60/90A. TUV approval

适用范围:

For Prepayment energy Meter and AMR system Combination switch, reactive power compensation devices and automatic control.

文件下载:

点击下载

 Speciality:

Coil pulse width

50msec. Min

Operation time

30msec. Max

Comeback time

30msec. Max

Dielectric strength


Between coil& contact

4000VAC

(50/60Hz) for 1 min


Between contacts

2000VAC

(50/60Hz) for 1 min

Insulation resistance

Min.1000M (500VDC)

 Ambient temp

-40℃~+70℃

 Weight

280g

 Quick connect

PCB&QC

 Plastic sealed dusted proof

Plastic package, dustproof


Output terminal (mm) not included in profile size

110 x 52 x 24


 Contact specification

 Contact form

3A  3B

Contact material

AgSnO2,

Contact resistance 

0.6mΩ Max.(12VDC 1A)

Contact current(Cosφ=1)

120A  250VAC

MAX disconnection voltage

440VAC / 110VDC

MAX disconnection power

30000VA

Electrical life

5×103cycles

Mechanical life

1×105cycles




Coil specification:        

(VDC)

Rated Voltage

(VDC) 

Suction and Release Voltage

(ms)

Pulse Width

(Ω)±10%

Coil Resistance(_)+10%

6V

≤4.2

≥50ms


TwinCoil

2ΩX7.5

9V

≤6.3

2ΩX17

12V

≤8.4

2ΩX28.5

6V

≤4.2

 

≥50ms


Unicoil

15Ω

9V

≤6.3

34Ω

12V

≤8.4

57Ω

 

 

 Installation Sizemm

图片1.png

Connection Diagram

 图片2.png

Application Notes

1. All the relays are shipped in the "operate" position because it is possible that during transit or final assembly the relay could change its state to the "release" position. please reset the relay into "operate" state when put in circuit according to need.

2. In order to maintain "operate" or "release" state of the relay, the coil voltage should reach the rated voltage. The pulse width should be 60ms or longer to ensure a proper change of state. Do not enegize both Pin1 and Pin2 at the same time on the coil for longer than 1 min (damage to the coil).

3. Relays are classified according to the polarity, if client need different form from information, please contact us.

4. The relay into the factory for destructive inspection should be protected from damage and strict distinction between the normal products.

5. Now with braided line relay, the load pin can not solder, not arbitrarily wrenched, two pins and righid fixation.

 



Contact specification
ParameterDate
Contact material AgSnO2 
Contact resistance

Max.0.6mΩ(12VDC 1A)

Contact currentt120A / 250VAC
Max disconnection voltage440VAC/110VDC
Max disconnection power30000VA
Electrical life5000 cycles
Mechanical life100000 cycles
Basic parameter
ParameterDate
Coil pulse widthMin. 50ms
Operation timeMax. 30ms
Comeback timeMax. 30ms
Dielectric strengthBetween contact & coil4000VAC 1min
Between contacts2000VAC 1min
Insulation resistance1000MΩ(at 500VDC)
Ambient temp-40~+70℃
Weight280g