4 Magnetic latching relay DS907H 120A - 广西睿奕科技开发有限公司 GUANGXI RAMWAY TECHNOLOGY CO LTD latching relay magnetic relay
Products Magnetic latching relay DS907H 120A

产品特性:

1.DS907H 120A is mainly used on export-type watches to replace two single-phase relays. The outlet mode is 1 in 2 out, 3 in 4 out. 2.The contact resistance can be below 0.8 milliohms for a long time, reaching UC2, UC3, and TUV requirements. 3.The overall heating condition is 50K at a rated current of 60/90A. TUV approval

适用范围:

For Prepayment energy Meter and AMR system Combination switch, reactive power compensation devices and automatic control.

文件下载:

点击下载

Speciality:

Coil pulse width

50msec. Min

Operation time

30msec. Max

Comeback time

30msec. Max

Dielectric strength

Between contacts and coils:

4000VAC

(50/60Hz) for 1 min

Between contacts

2000VAC

(50/60Hz) for 1 min

Insulation resistance

Min.1000M (500VDC)

 Ambient temp

-40℃~+70℃

 Weight

600g

 Quick connect

PCB&QC

 Plastic sealed dusted proof

Plastic package, dustproof

Size(mm)

135 x 58 x 30

 

 Contact specification

 Contact form

3A  3B

Contact material

AgSnO2,

Contact resistance 

0.8mΩ Max.(12VDC 1A)

Contact current(Cosφ=1)

120A  250VAC

MAX disconnection voltage

440VAC / 110VDC

MAX disconnection power

30000VA

Electrical life

1×104cycles

Mechanical life

1×105cycles

 

Coil specification:        

(VDC)

Rated Voltage

(VDC) 

Suction and Release Voltage

(ms)

Pulsewidth

(Ω)±10%

Coil Resistance

6V

≤4.2

≥50ms


Twin Coil

2Ωx5

9V

≤6.3

2Ωx11.5

12V

≤8.4

2Ωx20

6V

≤4.2

≥50ms


Unicoil

10Ω

9V

≤6.3

23Ω

12V

≤8.4

40Ω

 

 Installation Sizemm

21e9da3d1f5eafe044b2edd00b71da5.png

 Connection Diagram

 图片3.png

 Application Notes

 

1. All the relays are shipped in the "operate" position because it is possible that during transit or final assembly the relay could change its state to the "release" position. please reset the relay into "operate" state when put in circuit according to need.

2. In order to maintain "operate" or "release" state of the relay, the coil voltage should reach the rated voltage. The pulse width should be 60ms or longer to ensure a proper change of state. Do not enegize both Pin1 and Pin2 at the same time on the coil for longer than 1 min (damage to the coil).

3. Relays are classified according to the polarity, if client need different form from information, please contact us.

4. The relay into the factory for destructive inspection should be protected from damage and strict distinction between the normal products.

5. Now with braided line relay, the load pin can not solder, not arbitrarily wrenched, two pins and righid fixation.



Contact specification
ParameterDate
Contact material AgSnO2 
Contact resistance

Max.0.8mΩ(12VDC 1A)

Contact currentt70A / 250VAC
Max disconnection voltage440VAC/110VDC
Max disconnection power30000VA
Electrical life50000 cycles
Mechanical life100000 cycles
Basic parameter
ParameterDate
Coil pulse widthMin. 50ms
Operation timeMax. 30ms
Comeback timeMax. 30ms
Dielectric strengthBetween contact & coil4000VAC 1min
Between contacts2000VAC 1min
Insulation resistance1000MΩ(at 500VDC)
Ambient temp-40~+70℃
Weight600g