4
1.908M 70A is mainly used on export-type watches to replace two single-phase relays. The outlet mode is 1 in 2 out, 3 in 4 out. 2.The contact resistance can be below 0.8 milliohms for a long time, reaching UC2, UC3, and TUV requirements. 3.The overall heating condition is 50K at a rated current of 60/90A. TUV approval
For Prepayment energy Meter and AMR system Combination switch, reactive power compensation devices and automatic control.
Speciality:
Coil pulse width | 50msec. Min | |
Operation time | 20msec. Max | |
Comeback time | 20msec. Max | |
Dielectric strength | Between coil& contact | 4000VAC |
Between contacts | 1800VAC | |
Insulation resistance | Min.1000MΩ (500VDC) | |
Ambient temp | -40℃~+70℃ | |
Weight | 78g | |
Quick connect | PCB&QC | |
Plastic sealed dusted proof | Plastic package, dustproof | |
Size(mm) Output terminal (mm) not included in profile size | 54*30*18 |
Contact specification
Contact form | 2A 2B |
Contact material | AgSnO2, |
Contact resistance | 1.5mΩ Max.(12VDC 1A) |
Contact current(Cosφ=1) | 70A 250VAC |
MAX disconnection voltage | 440VAC / 110VDC |
MAX disconnection power | 20000VA |
Electrical life | 1×104cycles |
Mechanical life | 1×105cycles |
Coil specification:
Rated Voltage (VDC) | Resisttance ±10%(Ω) | Suction and Release Voltage (VDC) | |
Single | Dual | ||
6 | 16 | 8*2 | ≤70%Rated Voltage |
9 | 36 | 18*2 | |
12 | 54 | 27*2 | |
24 | 256 | 128*2 |
Installation Size(mm)
Connection Diagram:
Application Notes
1. All the relays are shipped in the "operate" position because it is possible that during transit or final assembly the relay could change its state to the "release" position. please reset the relay into "operate" state when put in circuit according to need.
2. In order to maintain "operate" or "release" state of the relay, the coil voltage should reach the rated voltage. The pulse width should be 60ms or longer to ensure a proper change of state. Do not enegize both Pin1 and Pin2 at the same time on the coil for longer than 1 min (damage to the coil).
3. Relays are classified according to the polarity, if client need different form from information, please contact us.
4. The relay into the factory for destructive inspection should be protected from damage and strict distinction between the normal products.
5. Now with braided line relay, the load pin can not solder, not arbitrarily wrenched, two pins and righid fixation.
Parameter | Date |
---|---|
Contact material | AgSnO2 |
Contact resistance | Max.1.5mΩ(12VDC 1A) |
Contact currentt | 70A / 250VAC |
Max disconnection voltage | 440VAC/110VDC |
Max disconnection power | 20000VA |
Electrical life | 10000 cycles |
Mechanical life | 100000 cycles |
Parameter | Date | |
---|---|---|
Coil pulse width | Min. 50ms | |
Operation time | Max. 20ms | |
Comeback time | Max. 20ms | |
Dielectric strength | Between contact & coil | 4000VAC 1min |
Between contacts | 1800VAC 1min | |
Insulation resistance | 1000MΩ(at 500VDC) | |
Ambient temp | -40~+70℃ | |
Weight | 78g |