4 Current transformer - 广西睿奕科技开发有限公司 GUANGXI RAMWAY TECHNOLOGY CO LTD latching relay magnetic relay
Products Current transformer

产品特性:

适用范围:

Current Transformer for electrical meter,energy meter

文件下载:

Current Transformer for  electrical meter,energy meter

 

DCCT29_.jpg

1.jpg2.jpg3.jpg5.jpg4.jpg

Parameter and Performance

Primary Current

Secondary

Rate Current

Accuracy 

Class

Load

Ω

Ambient 

Temperature

Humidity

Rated 

Current

Max. 

Current

4mA

0.1

10

-40°C~70°C

≤98°C

10A

100A

 

Accuracy Class

0.1

Rate Current(%)

5

20

100

120

200

400

Imax.

Current Errorv±(%)

0.1

0.1

0.1

0.1

0.1

0.1

0.1

Phase Error±(%)

8

5

5

5

5

5

5

 

Specification

1.5(6)A/0.6mA

5(20)A/2.5mA

5(30)A/2mA

5(30)A/2.5mA

5(40)A/2mA 

5(40)A/2.5mA

5(50)A/2mA

5(50)A/2.5mA

5(60)A/2mA

5(60)A/2.5mA 

5(80)A/2mA

5(100)A/2mA

5(100)A/2mA

10(40)A/4mA

10(40)A/4mA 

10(40)A/5mA

10(60)A/2mA

10(60)A/4mA

10(60)A/5mA

10(80)A/4mA 

10(100)A/4mA

10(100)A/5mA

15(60)A/5mA

15(60)A/6mA

15(90)A/7.5mA 

15(100)A/10mA

20(80)A/8mA

20(80)A/10mA

20(100)A/7.5mA

20(100)A/8mA

20(100)A/10mA

30(100)A/15mA




 

 Instructions

 (1) Accord with JB/T10665-2006 in transformer requirement, applicable to single phase meter or three-phase electronic electric energy meter in the power frequency voltage of 50(60) Hz. 

 

(2) Power frequency voltage withstand test between first winding and second winding. Second winding is grounding, between first winding and second winding add with AC3KV, the leakage current is set to 1mA, no breakdown in continuing 1min. 

 

(3) Winding insulation resistance requirements: In 500V DC voltage, first and second winding insulation resistance is not less than 1GΩ. 

 

(4) Load power test: Under rated load, impact after half of period by 30Imax current, transformer is still intact. While returning to rated current work, transformer error do not exceed the specified error limit of 1.3times.After demagnetizing, transformer satisfy the accuracy rating requirements 

 

(5) Temperature rise limit: In accordance with the provisions of GB/T17215temperature rise influence, at an ambient temperature of 40° C, in the Imax current transformer casing surface temperature does not exceed 25K.

 

(6) Pulse voltage value in accordance with the provisions of GB/T17215 electrical test requirements: First winding and second winding can bear 6kV positive, negative impulse voltage of 10 times; minimum interval between pulse voltage is 3S.

 


 

 

Parameter and Performance

Primary Current

Secondary

Rate Current

Accuracy 

Class

Load

Ω

Ambient 

Temperature

Humidity

Rated 

Current

Max. 

Current

4mA

0.1

10

-40°C~70°C

≤98°C

10A

100A

 

Accuracy Class

0.1

Rate Current(%)

5

20

100

120

200

400

Imax.

Current Errorv±(%)

0.1

0.1

0.1

0.1

0.1

0.1

0.1

Phase Error±(%)

8

5

5

5

5

5

5

 

Specification

1.5(6)A/0.6mA

5(20)A/2.5mA

5(30)A/2mA

5(30)A/2.5mA

5(40)A/2mA 

5(40)A/2.5mA

5(50)A/2mA

5(50)A/2.5mA

5(60)A/2mA

5(60)A/2.5mA 

5(80)A/2mA

5(100)A/2mA

5(100)A/2mA

10(40)A/4mA

10(40)A/4mA 

10(40)A/5mA

10(60)A/2mA

10(60)A/4mA

10(60)A/5mA

10(80)A/4mA 

10(100)A/4mA

10(100)A/5mA

15(60)A/5mA

15(60)A/6mA

15(90)A/7.5mA 

15(100)A/10mA

20(80)A/8mA

20(80)A/10mA

20(100)A/7.5mA

20(100)A/8mA

20(100)A/10mA

30(100)A/15mA




 

 